(15 + 2.9L) in Glass scales EZ Up to 8 in (Z-axis) (41 + 3.2L) in Gage blocks Squareness ESQ Up to 8 in (Z-axis) (19 + 130L) in Ballbar Probing Performance PF2D, PFV2D Diameter Measured: (0.012 to 0.12) in (0.12 to 0.4) in.
![iso 17025 2017 quality manual pdf iso 17025 2017 quality manual pdf](https://docplayer.net/docs-images/47/21029941/images/page_11.jpg)
#ISO 17025 2017 QUALITY MANUAL PDF ISO#
ISO 10360-7 (Unidirectional) Length Measurements EUX, EUY, EUXY Up to 24 in (23 + 2.9L) in Glass scales EUV Up to 2 in.
![iso 17025 2017 quality manual pdf iso 17025 2017 quality manual pdf](https://3npriz2azt5rxu3g21cu08z1-wpengine.netdna-ssl.com/wp-content/uploads/2018/08/LQMS-Forms-Image-1024x793.jpg)
Parameter/Equipment Range CMC 2, 4 ( ) Comments Bore Gages 3 Up to 12 in 22 in or 0.6R (whichever is greater) SIP302M Box Parallels Parallelism Squareness 5 in 10 in 10 in 5 in 10 in 10 in 28 µin 12 µin/in + 38 µin Gage amp w/probe, cylindrical square Calipers 3 (Including Intertest, Oditest, Snap Jaw and other OD Calipers) Resolution 0.0001 in Up to 2 in (2 to 12) in 78 µin 70 in + 4 in/in Gage blocks Resolution 0.0005 in Up to 24 in (24 to 60) in 450 µin 340 in + 3.7 in/in Resolution 0.001 in Up to 30 in (30 to 100) in 840 µin 700 in + 3.4 in/in Chamfer Gages/Hole Up to 12 in 20 in + 0.6R Cylindrical rings Gages 3 Clinometers and Inclinometers, and Electronic Levels Up to 360 0.18 arcseconds + 37 parts in 10 6 Sine bar/gage blocks CMMs Imaging (Video CMMs/Vision Systems) 3 XY diagonal up to 36.5 in. probe, indi-square and test indicator Articulating Arm 3 (CMM) ASME B89.4.22-2004 Single Point Articulation Max Deviation 2sSPAT (2 to 10.5) ft 110 µin (2.8µm) 22 µin (0.56 µm) Effective Diameter 1 in (25.4 mm) 82 µin (2.1 µm) Volumetric Max Deviation Range 2RMS (16 to 36) in (52 to 76) in (16 to 36) in (52 to 76) in (16 to 76) in 60 µin + 7.5 µin/in 60 µin + 7.0 µin/in 85 µin + 11 µin/in 85 µin + 9.9 µin/in 0.98 µin/in Bench Center Center Parallelism Up to 24 in (68 + 4L) µin Gage amp w/probe Base Flatness & Base Parallelism Up to 24 in (62 +2.5L) µin (A2LA Cert. Dimensional Parameter/Equipment Range CMC 2, 4 ( ) Comments Angle Blocks Up to 60 (0.36 + 1.1 *Ө/20) arcsec, Sine bar, gage blocks, gage amp & probe, Where Ө = angle Angle Plates 3 Up to 48 in 65 µin or (12 µin/in + 30 µin), whichever is greater Gage amp. Parameter/Equipment Range CMC 2 ( ) Comments ph Meters 3 4 ph 7 ph 10 ph 0.011 ph 0.011 ph 0.012 ph Standard buffers III.
![iso 17025 2017 quality manual pdf iso 17025 2017 quality manual pdf](https://images-na.ssl-images-amazon.com/images/I/51WK9U9JOiL._SX384_BO1,204,203,200_.jpg)
![iso 17025 2017 quality manual pdf iso 17025 2017 quality manual pdf](https://i.pinimg.com/736x/9b/ca/9a/9bca9aef8f3f82bb9432aa6fa0a98655.jpg)
Acoustical Quantities Parameter/Equipment Range CMC 2, 8 ( ) Comments Sound Level Source (85 to 140) db 0.20 db + 0.032 % Piston phone, transducer Measure (Meters) (20 to 140) db 0.32 db Sound level calibrator Sound Level 3 Source/Measure (Meters) (20 to 140) db 0.60 db Sound level calibrator II. 10 7350 North Teutonia Avenue Milwaukee, WI 53209 Dainna Lowrance Phone: 4 CALIBRATION Valid To: Certificate Number: 1078.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1, 10 : I. SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 TRESCAL, INC.